I-Blast Beta

I-Blast > Blast management > Measurements > Results > Seismograph
I-Blast > Blast management > Design > Measurements > Results > Seismograph


This window is used to manage the seismic records used in I-Blast 8 and to perform certain operations on them.

Overview

Fenêtre de gestion des enregistrements sismiques

General description

The window is in 4 parts.

Adding a record

Creation and features

The 'Add' button is used to create a record in the database, which can then be used to store seismic data. Records can have the following characteristics:

The reference distance and charge / delay associated with the signal can be edited in the two associated fields at the top of the table.

Importing a seismic file

The Files button lets you import signals in the various formats supported by I-Blast 8.
When this window opens, a file selector appears, offering different filters according to the formats accepted.

The imported signal will be saved in the currently selected record. If this record already contains a signal, it will be overwritten.

Fenêtre d'importation d'un fichier sismique

Once selected, the signal is displayed for preview to ensure that it is the desired signal.

The Import button validates the saving of this signal in the selected record.

The Don't import button closes the window without saving the signal in the selected record.

Supported formats/brands

Importing a CSV file

The Import CSV button lets you import signals in text format.

The imported signal will be saved in the currently selected record. If this record already contains a signal, it will be overwritten.

First section: Selecting the seismic file to be imported

Fenêtre import signal textuel

Second section: Select fields for each column

Fenêtre import signal textuel

The second section links the columns in the file to the information needed to import the signal.

The following parameters cannot be read or inferred and must be entered manually to ensure a consistent signal:

Third panel : Seismic Trace Preview

Fenêtre import signal textuel

This third and final section is used to check that the signal to be imported corresponds exactly to what is expected.

The checkboxes next to L Axis, T Axis, V Axis and S Axis allows you to choose not to import certain channels.

Supported formats/brands

Theoretical signal generation

The Generate button allows you to create different theoretical signals based on certain parameters.

The generated signal will be saved in the currently selected record. If this record already contains a signal, it will be overwritten.

Fenêtre de génération d'un signal sismique théorique

The module offers three types of signal: Sinus, Cardinal Sinus and Damped Sinus.

They all take the following parameters:

The Damped Sinus also takes on a Damping parameter.

The Generate button lets you preview the requested signal.
The OK button saves the signal in the current record and closes the generation window.
The Cancel button closes the window without saving the generated signal.

Record operations

Concatenation

The Concatenate button is used to join several records end-to-end.
The order of selection is important.
The resulting signal is made up of all the selected signals placed end-to-end in the order of selection.

When you click on the button, a window appears, allowing you to enter the device's "pre-trigger" time.
This value takes into account the redundant part of the signals when they come from a device with a pre-trigger.

Cutting

The 'Cut' button lets you keep only part of a signal.
The part of the signal visible in the graph will be copied to a new record. This new record will bear the name of the original with the suffix "_cut".

Example:
For a record named "signal", the recut record will be named "signal_coupé".

Deleting a record (Del)

The Del. button allows to delete a record definitively after confirmation.

Calculation of Vp

This module calculates the speed of wave propagation from a complete record (seismic + sound).
The fields used in the calculation are :

The Auto button allows you to search for signal arrival times automatically.

The Wave speed P field displays the result of the calculation. This can be saved in the information area associated with the record via the floppy disk button next to it.

The greater the expected Vp, the more accurate the data must be (distance to the blast, temperature, and wavefront times).
Indeed, for Vp > approximately 2000 m/s, a very slight variation in the arrival times of the wave fronts causes a very large variation in Vp, as can be seen in the curve below:
courbe Vp fonction de dt
(Example with Distance = 100m et Vair=330m/s, dt = Time air - Time ground)

If Wave speed P field is empty after the calculation it means that dt is greater than the max value possible to do the calculation (display by the dashed red line on the above graph)

K calibration

This function lets you quickly re-calculate the K value of the attenuation law using the signal's PPV, the distance between the zone and the blast, the Charge / delay of the blast and a given alpha.

The function re-calculates the K of the seismic and aerial law.

Clicking on the floppy disk button 💾 saves the new K value in the area associated with the signal.


  1. Peak Particule Velocity ↩︎

  2. Peak Vector Sum ↩︎