I-Blast > Blast management > Blasts > 3D > Simulation > 4D simulation > Results management > Display fragmentation distribution
Overview
This window displays the fragmentation results of a 4D simulation.
It also allows you to calibrate these results so that they match the measured fragmentation.

General information
-
The distribution title above the value table indicates the perimeter on which the distribution is calculated.
It may indicate:- “Fragmentation distribution of all voxels”.
- “Fragmentation distribution of voxels in %POLYGONE% ( %ZMIN% < Z < %ZMAX%)”.
%POLYGONE%: name of the selected polygon in which fragmentation is calculated
%ZMIN%/%ZMAX%: Z bounds between which fragmentation is calculated
-
The
Applybutton
This button is used to validate display or calibration modifications made in the window.
If the window is closed without first pressing the
Applybutton, changes will not be taken into account.If the 4D simulation has already been saved, pressing the
Applybutton does not modify the saved display and calibration parameters.
To do this, save the 4D simulation again and select theReplaceoption.
Value table
The table of values contains the fragmentation distribution in numerical form.
Each line represents a distribution class.
For each class, there are 4 columns:
Class: size value of the fragmentation class.
It is possible to modify the distribution classes by directly modifying the values in the column.
To add a new class, enter its value in the empty line below the last class.
To delete a class, delete or set its value in the column to 0.
Each time a class is modified/added/deleted, the table is automatically sorted in ascending order of class, and the values of the other columns are recalculated at the end of input.%: Represents the % value of fragments in the class.
This corresponds to the proportion of materials whose fragmentation is between the value of the previous class and the current class.
For example, if the value of class 100mm is 15% and the previous class has a value of 50mm, this means that 15% of materials have a size between 50mm and 100mm.Cumulative: Cumulative % of the class. This corresponds to the value of the passing at this class.Color: This color is used for 3D voxel display when theBlast voxel/Fragmentationcolorization option is used.
In this case, each voxel will take on the color of the class corresponding to its calculated fragmentation.
The Passing at field below the table allows you to quickly read the size of passing at a defined %.
Distribution graph
Graphical representation of fragmentation distribution.
A bubble cursor allows you to read the graph values as you move your mouse over them.
The Log scale option at the bottom left of the window lets you choose the type of scale to use to represent the distribution.
If checked, a logarithmic scale will be used for the x-axis, otherwise a linear scale will be used.
| Logarithmic scale | Linear scale |
|---|---|
![]() |
![]() |
Calibration

This section contains tools for calibrating fragmentation results.
By default, it is folded. To unfold it, click on the
button.
Calibration coefficient
There are 2 fragmentation calibration parameters:
- The
scale coefficient: stretches/compresses the fragmentation curve horizontally.
This is a positive number whose default value is 1. - The
Offset: shifts the fragmentation curve horizontally by the offset value.
Offset can be positive or negative.
The transformation performed for each fragment composing the fragmentation distribution is :
Calibrated size = (Scale coefficient * Size) + Offset
Actual distribution
This tool allows you to import the measured distribution and display it on the graph as an aid to calibration.

The
button imports directly the measured distribution of the DNA-FragSize module.
The
button allows you to import a distribution from a csv file.
The display color of the curve can be changed using the color selector.
Calibration tool
The Auto button automatically searches for calibration parameters.
The Error field displays the mean value of the deviation in % of passing between the simulated and measured cumulative curves.
The closer this value is to 0, the better the calibration.
If the last modification to the calibration parameters reduced the error, the field will be displayed in green:

Otherwise, if this modification has increased the error, it will be displayed in red: