I-Blast > Blast Management > Blasts > Design > Design > Holes > Misc. > Paths
Overview

This window is used to create "paths".
Paths are defined for each hole by a group number (the "path") of a different color and an index in the sequence (from 1 to the number of holes in the path).

These paths can represent a drilling or a programming order, for example.
Timing export functions for electronic detonators use these paths to define the programming order.
The Place new hole, Band width and Reverse order fields are hidden by default.
To display them, click on the
button.
Click on the
button to hide them again.
Paths edition
The Sequence button is used to enter path cabling mode.
Once in this mode, click on a first hole to initiate wiring.
Depending on the state of the first hole:
- If the first hole doesn't belong to any path, this hole will be added to the path defined by the
Groupfield.
It will be placed at the beginning or end of the sequence according to the option defined byPlace new hole. - If the first hole already belongs to a path, the
Groupselector will automatically be set to the hole group in order to continue wiring this path.
The hole will keep its current order in the sequence.
After clicking on the first hole, the other holes can be wired in a similar way to the timing design.
The only difference is that this wiring is linear and does not accept branches (one hole cannot be wired to several subsequent holes).
When wiring, subsequent holes are added in the order of the path sequence after the first hole.
If any wired holes belong to another path, they will be removed from that path and added to the path being wired.
Hole indexes in paths are automatically updated as wiring proceeds.
When wiring from one hole to another, all holes in between will be included in the path.
The Band Width allows you to define the band around the segment between the two holes, in which the intermediate holes will be taken into account.
This value can be modified in the field, but also when wiring, using the A key to reduce it by 0.1m and Z to increase it by 0.1m.
It is possible to wire one hole directly to another without taking intermediate holes into account by holding SHIFT or D when clicking on the second hole.
Double-clicking on the plan, pressing Esc or closing the path window will exit the path wiring mode.
The Delete button removes the selected holes from the paths.
The Delete all button deletes all paths from the blast plan.
The Reverse order button reverses the sequence of the path selected by the Group field.
The direction of the path (1 -> n) is reversed (n <- 1).