I-Blast Beta

I-Blast > Blast management > Blasts > Design > Zoom / Select > Inspector


Preview

Inspector

This window lets you access and modify all the information available on a hole.
It is divided into 4 tabs:

To inspect a hole, simply click on it on the blast plan when the inspector is open.

Loading

This tab allows you to view and modify hole loading.
It is divided into several sections.

Loading display

Located on the left, this section contains a graph showing the hole's loading.

Above is a D field indicating the hole diameter.
Underneath, the Text size potentiometer adjusts the size of the text on the drawing.

You can select a charge by clicking on it on the graph.
The selected charge is framed in red and its details are displayed in the right part of the window.

Selected charge details

Located in the top right-hand corner, this section displays and allows you to modify information about the selected charge.

The Charge # field displays the index of the selected charge. The arrows on either side of this field allow you to move quickly from one charge to another.

The Cartridges, Height and Quantity fields let you modify the quantity of explosive in the selected charge.
The arrows on either side of these fields are used to increment or decrement by a value of 1 the number of cartridges, the charge height in meters or the quantity of explosive in kg.

The + Insert button adds a charge in the hole bellow the selected charge.
When clicking on this button, the explosive selection popup opens in order to select the explosive for this new charge.

The - Delete button removes the selected charge from the hole.

When the selected charge is the top one and is a stemming charge, the Complete button appears and allows you to complete the hole with this charge.

The fields below, from Bottom to VoD @ D, display various charge and explosive information.

The Color selector is used to change the color of the charge.

The fields bellow allows to modify the charge initiation options.
Top Det and Bottom Det add a detonator at the top or bottom of the selected charge. If a detonator is added, it is possible to modify the type of detonator using the combo and the detonator time using the (ms) field.
Top booster and Bottom Booster add a booster at the top or bottom of the selected charge. If a booster is added, it is possible to modify its weight using the field bellow the option.
Detonating cord adds a detonating cord along the selected charge. It is possible to modify its weight using the field that appear near the option.

Different types of detonator are available, with differences in the calculation of the associated absolute detonation time :

  • Undefined : same behavior in the calculation as Electric detonator
  • Nonel : detonation absolute time = surface time + detonator time + propagation time of the shock wave in the hole
  • Electric : detonation absolute time = surface time + detonator time
  • Electronic : same behavior in the calculation as Electric detonator
  • Electronic (Absolute time) : detonation absolute time = detonator time (surface time is ignored)


The Absolute timing option displays the detonator time in absolute time on the hole drawing, the calculation of which depends on the type of detonator.
If this option is unchecked, the detonator time will be displayed.

If quantities/heights of explosives have been modified in the inspector, a cross appears on the hole in the blast plan to indicate that the loading template has been adjusted manually :
modified hole
If a load has been added or removed, the color of the hole is changed to indicate that it no longer conforms to the model.

Statistic

Located at bottom right, this section displays hole and loading statistics:

Details

Details tab

This tab allows you to consult various information related to the inspected hole.

Some of these properties can be modified directly from this window by checking the Edit box in the bottom right corner.
Checking this box unlocks the fields that can be modified.
These fields depend on the state of the hole. For example, it is not possible to modify the diameter or depth of a loaded hole.

To apply the changes, click on the ✅ Modify button that appears when the box is checked.

In addition, when the box is checked, the following function appears at the top right of the tab:
Create a loading hole template
This function allows you to create a loading template from the current loading of the inspected hole.
This can be useful for creating models from an imported shot or from a hole modified in the inspector.
To do this, enter the name of the model to be created in the "Model name" field, then click on the Create a loading hole template button.

Bench

Bench tab

This tab displays the hole's free face profile, deviation profile and drilling log.

On the graph, the free face profile is represented by a black line.
In the case of a hole with no free face, it is replaced by a dotted line at the value of the burden.
The deviation is represented by a thick blue line.
The third curve represents the drilling log. Its color varies according to the type of drilling parameter displayed: gray for raw parameters, blue for combined parameters (TBT, Somerton or Energy) and dark red for the calibrated UCS value.

The potentiometer on the right of the drawing modifies the depth of the profiles interrogation function. This function is displayed as a line to the free face profile and displays the exact values of the bench, powder factor and drilling parameter at the selected depth.

Use the selector at bottom right to choose which drilling log parameter to display.
It is also possible to modify the max scale of this parameter. The drilling parameter curve varies from 0, close to the hole, to the maximum value entered in this field, on the right of the drawing.

Several additional display options are available :

The checkbox in front of the Powder factor color scale colorizes the free face profile according to the powder factor
This checkbox has 3 states.
Clicking on it again colorizes the free face profile according to the burden.
Clicking on it a third time deactivates free face profile coloring.
It is possible to modify the color scale of the powder factor or burden by changing the min and max scale values.

The Export button at the top right of the drawing displays the free face profile points in csv format in a text box.

Seismic trace

Seismic trace tab

This tab displays an overview of the seismic trace (signature hole signal) assigned to the inspected hole and its information.

Hole info

infoTrou

This tab displays various information about the selected hole: