I-Blast Beta

I-Blast > Blasts management > Analysis > Compare


Global

CAP_Summary

This window compares two blasts selected in the blasts management table in the form of a graphical representation.
The comparison is based on several aspects of the blast:

The names of the blasts compared are displayed in the window title bar.

The buttons at the top left of the window are used to toggle between the comparison summary and these different sections.

Useful commands for 2D drawings :

For each blast aspect, a table gives details of the holes.
In these tables, columns marked 1 are relative to blast 1 of the comparison and columns marked 2 are relative to blast 2.

Association of holes between the two blasts

For each hole in blast 1, a search is made using the 2D position on blast 2. If the 2D distance between the two holes is less than the distance entered in the parameters, the holes are considered to be associated.
It is therefore on these associated holes that all the comparisons will be made.

Matching

Summary

CAP_Summary

This section provides a summary of the comparison between the two blasts, so that you can see easily where are the differences.

This summary uses pie charts to show the percentage of :

Moreover, a general summary is available to provide an overview of all aspects of the blast.
In the general overview a hole is counted as modified if it is counted as modified for any other category (geometry, loading, sequence).

Parameters

CAP_Parameters

From this screen, it is also possible to change the parameters for comparing the two blasts.
These settings can be accessed via a panel that can be opened and closed using the tools button at the top right of the window.

These parameters are :

The Validate button is used to apply the changes made on the parameters entered. The various screens will be refreshed using the new parameters.

The Reverse blasts button reverses the order in which blasts are compared. Blast 1 will become blast 2 and vice versa.

Report

The IMG_Pdf button at the top right of the window generates a PDF document of the entire comparison of the two blasts.

If a table filter is applied, this will also be taken into account when editing the tables in the report.

Geometry

CAP_Geometry

The Geometry screen displays a graphical representation highlighting the geometric differences of each hole:

A hole associated between the two blasts is considered to be geometrically modified if the 3D distance at the head or the 3D distance at the bottom between its position in blast 1 and its position in blast 2 is greater than the Tolerance on position.

In the cross-section below the blue line represents the reference hole from blast 1, the dotted circles represent the distance corresponding to the Tolerance on position. The orange line corresponds to the matched hole from blast 2. If only one of the ends (head or bottom of the hole) is within tolerance then the hole is considered modified. If both are within tolerance then the hole is considered identical.

Geometry

If a difference is detected, the hole will be displayed as Modified following the colour of the legend (orange).

The information displayed at the top right of the map corresponds to :

The table in the panel at the bottom of the window allows you to view the values of the attributes of the geometry of the two blasts for each hole.

Loading

CAP_Loading

The Loading screen displays a graphical representation of the blast2, highlighting the loading differences for each hole:

An associated hole between the two blasts is considered modified from the point of view of loading:

If a difference is detected, the hole will be displayed as Modified following the colour of the legend (orange).

The information displayed at the top right of the map corresponds to :

When a hole is selected, a panel corresponding to the loading display appears on the right of the window.
This representation is used to analyse differences of loading in the hole. When a difference is detected, an orange border will be displayed around it.

When you hover over the load display, the details of the charge or the difference between the two charges will be displayed at the bottom of the graph.

The table in the panel at the bottom of the window shows, for each hole, the values of the loading attributes for blast1 compared to blast2.

The load differences not considered are :

  • Explosive characteristics
  • Type of detonator
  • The weight of the explosive cord

The weight of the booster is added to the weight of the charge and is therefore taken into account when detecting a change in the loading.

Sequence

Timing

CAP_Timing

The Timing screen displays a graphical representation of the blast2 highlighting the differences in timing for each hole:

A hole associated between the two blasts is considered to be modified from the point of view of timing if the detonation time (at the head or bottom) between the holes of blast1 and those of blast2 is greater than the Tolerance on detonation time.

If a difference is detected, the hole will be displayed as Modified following the colour of the legend (orange).

The information displayed at the top right of the map corresponds to :

The table in the panel at the bottom of the window allows you to see, for each hole, the values of the timing attributes for holes in blast1 compared with holes in blast2. By clicking on the chevron of a line in this table, it is also possible to compare in detail the attributes of the detonators presented in the hole for blast1 and blast2.