I-Blast > Blast management > Analysis > Seismic > Attenuation law
I-Blast > Blast management > Blasts > Design > Analysis > Charge > Attenuation law
Overview

This window is used to create the attenuation laws required for seismic and overpressure simulations.
General principle
For seismic level calculations using the charge per delay method, the formula used is:
$\ PPV=K*Sd^\alpha$
In this formula :
-
PPV : Peak particule velocity (mm/s)
This value corresponds to the maximum of the velocity absolute value of the seismic signal on the three channels. -
Sd : Scaled distance - compound value of the blast distance from measuring point D and the blast charge per delay Q.
There are several possible formulas for scaled distance according to different studies.
Here are the most common:- Chapot formula $\ Sd=D/\sqrt$
- Hendron formula $\ Sd=D/\sqrt3$
- Langefors formula $\ Sd=Q/D^$
-
K et α (alpha) : attenuation law coefficients.
The aim of this module, constructing an attenuation law, is to find a value for these coefficients. These coefficients will then be used in seismic calculations using the charge per delay method.
The coefficients of the attenuation law are determined using a logarithmic linear regression.
Indeed $\ log(PPV)=log(K)+\alpha*log(Sd)$
log(K) therefore corresponds to the y-intercept of the linear regression and Alpha to its slope.
Attenuation laws can also be realized using PVS (Peak vector sum), which is the maximum of the vector resultant of the three signal channels.
The formula used is the same, replacing PPV by PVS.
The construction of an attenuation law and its use to calculate seismic levels must be carried out under the same conditions to be meaningful:
- The same formula of the scaled distance must be used for the construction of the law and its application.
- A law built with PPV values will give PPV results, and a law built with PVS values will give PVS results.
It is therefore necessary to make an choice beforehand of the formula and value to be used in the options.
For air overpressure simulations, the formula used to calculate the maximum value is the same as for seismic simulations, but the reduced distance formula used is identical to that of Hendron.
Attenuation law
Blast selection
The Select section of the Blast tab is used to select the site seismic signals to be used to construct the attenuation law.
The table shows all seismic signals for the current site.
It is possible to filter or sort them using the table tools.
To create the attenuation law, select at least three records in the table.
The fields above the table show the coefficients calculated for seismic and air attenuation laws.
There are two K coefficients for each of the laws :
K VibandK Airare the average coefficients for the seismic and air attenuation laws.K n%with n ranging from 50 to 100, correspond to the K calculated with a confidence interval.
This value is detailed in the next section.
The r2 fields correspond to the coefficient of linear determination of the vibration and air attenuation laws. The closer this coefficient is to 1, the better the quality of the regression is.
This coefficient is calculated on the mean attenuation law; the confidence interval is not taken into account.
The
button opens an attenuation law calculator.
The
button saves the displayed attenuation law to the current blast (the opened blast if this window is opened from the design window or the blast selected in the table if this window is opened from the blast management).
Depending on the options, the attenuation law will be saved in the blast geology and/or in the zones used for its construction.
The Load associated data from input field and the two adjacent buttons are used to save and reload record selections for law construction.
To save a record selection, enter a name for the selection in the input field and save the attenuation law with the
button. The selection will be saved at the same time.
To load a record selection, enter its name in the input field or select it from the drop-down list in the field, then click on the
button.
To delete a saved selection, enter its name in the input field or select it from the drop-down list in the field, then click on the
button.
The Floating graph checkbox displays the attenuation law graph, described in the next paragraph, in a separate window.
Attenuation law (Ground)

This tab displays the attenuation law defined by the previous selection in graphical form.
On this graph, each selected record is represented by a point.
Two lines are displayed on the graph:
- in grey the average attenuation law corresponding to
K Vib - in red, the attenuation law with confidence interval corresponding to
K n%
The confidence interval corresponds to the percentage of points below the line.
K50% indicates that the line passes through the middle of the points, K100% indicates that all points are below the line.
Another way of looking at it is to say that, based on the history used to construct the law, there is an n% chance that the actual PPV value obtained during the blast will be lower than the PPV calculated using Kn%.
So, to make a simulation giving the most probable value, K50% should be used and to make a conservative simulation giving the most pessimistic value, K100% should be used.
The confidence interval (n%) can be modified using the slider at the top left of the window.
By hovering over the points on the graph, you can obtain information about them directly on the graph (blast and zone) and more detailed in the message bar at the bottom of the window (blast, zone, D, Q, PPV).
Points can be removed from the attenuation law by right-clicking on them and selecting the Delete option.
This allows you to quickly eliminate any outliers.
Abacus (Ground)
This tab displays a chart for determining the PPV for a given charge per delay and distance.
Attenuation law (Air)
This tab is identical to the Attenuation law (Ground) tab, but for the air overpressure law.
Options

This section lets you modify the parameters of this module.
The options available under the Save to header are used to select what should be saved when the
button is clicked.
The
button next to these options has the same effect than the one in the blast selection section.
The Scaled Distance formula selector allows you to choose the formula to be used for constructing the attenuation law.
The chosen formula is saved for the site and affects the attenuation law as well as all vibration calculations using the charge per delay method in the site.
You can choose one of the predefined formulas or define a custom formula.
The Calculation mode selector allows you to choose if the attenuation law is to be calculated using the Maximum (PPV) or the PVS of each record.
If you choose the PVS option and build a PVS attenuation law, the results of charge per delay vibration calculations using this law correspond to PVS values.
This is the case even if the I-Blast labels indicate PPV.
The Update Dist button forces the recalculation of the distance between the blast and the zone for all records of the type Full Blast selected in the table of the Select section.
The Update CU button forces the recalculation of the charge per delay for all records of the type Full Blast selected in the table of the Select section.
The charge per delay calculation will use the time window indicated in the adjacent field.
K, Alpha auto

This section lets you define automatic selection filters for the records to be used to construct an attenuation law for the current blast and a zone.
Records can be filtered according to :
- type of signal (
Full blastand/orSingle Hole). - date of blast in relation to current blast (in months)
- distance from current blast in XY and Z
- the
Blast-zone orientation variation.
This is the azimuth difference between the blast -> zone orientation of the record to be selected and the current blast -> zone orientation. - the
Zone activestatus of the zone associated with the record.
If this option is enabled, only records associated with an active zone (in the blast to which the record is attached) will be considered.
The slider below the filters lets you choose the confidence interval to apply to the attenuation law formed by the selected records.
The Minimum correlation (r2) field lets you add an acceptance criterion on the r2 of the law, to avoid its use if the records do not correlate sufficiently.
The Save parameters button saves the attenuation law construction parameters for the site.
These parameters will be used to refresh the K and Alpha values of the blast's active zones when the Auto K, Alpha option of the design window is clicked.
It is also possible to preview the law that will be used for a zone in the current blast, using the
button.
This button will automatically select from the table in the Select section the records retained by the filters defined for the selected zone.
Calculator
The
button opens a calculator allowing you to apply the attenuation law in different ways:

The K and Alpha coefficients can be used to calculate any of the following :
- Q from D and PPV
- D from PPV and Q
- PPV from Q and D
When using a custom scaled distance formula, only the PPV from Q and D option is available.